Panasonic air conditioner error codes: what they mean and what to do


A Panasonic air conditioner shows a fault by stopping and blinking its TIMER lamp; the code itself, such as H11 (indoor/outdoor communication), H19 (indoor fan motor lock) or F91 (refrigeration cycle abnormality, usually low refrigerant), is read with the CHECK button on the remote. This guide from LE Company, air conditioning engineers in London, takes the meanings from Panasonic’s own operating instructions and service manuals for the Etherea and TZ wall units and multi-splits. Commercial PACi systems use a different code list, covered below. For repairs, see our Panasonic air conditioner repair page.
Need an engineer? LE Company repairs Panasonic air conditioning across London. Call +44 20 3603 7172, Monday to Saturday 8am to 8pm, or see Panasonic air conditioner repair.
Every repair we do starts with checking and cleaning the system. Many of the faults behind these codes, from a frozen indoor coil to an overheated outdoor unit, come from blocked filters, a dirty coil or a blocked condensate drain, and after a proper service the code often does not come back. That is why we service first and replace parts only when a test shows the part is faulty. See what an air conditioning service covers.

How to read a Panasonic error code with the CHECK button

From Panasonic’s instructions: when the TIMER lamp blinks, press and hold CHECK on the remote for 5 seconds until the display shows "- -". Press the timer up or down button: each press sends the next code to the unit, starting at H00. When the code matches the stored fault, the unit beeps for about 4 seconds and the power lamp lights; write the code down. Hold CHECK for 5 seconds to leave, or wait 30 seconds. Panasonic then says to switch the unit off and give the code to an authorised dealer. The last code stays in memory after a restart.

Panasonic air conditioner error codes (Etherea, TZ, multi-split)

Code
Panasonic meaning
What the engineer checks
H00
No memory of failure
-
H11
Indoor/outdoor abnormal communication
Wiring and terminals between the units, control boards
H12
Indoor capacity unmatched (multi-split)
Combination of units
H14
Indoor intake air temperature sensor abnormality
Sensor, lead, connector
H19
Indoor fan motor mechanism lock
Fan motor, lead, connector, blockage
H23
Indoor heat exchanger temperature sensor abnormality
Sensor; limited cooling still possible
H27
Outdoor air temperature sensor abnormality
Sensor
H28
Outdoor heat exchanger temperature sensor abnormality
Sensor
H97
Outdoor fan motor mechanism lock
Fan motor, lead, connector, blockage
H98
Indoor high pressure protection (heating)
Airflow, filter, refrigerant circuit
H99
Indoor freeze protection (cooling)
Dirty filter or heat exchanger, airflow
F11
4-way valve switching abnormality
4-way valve, lead, connector
F90
Power factor correction (PFC) circuit protection
Outdoor control board
F91
Refrigeration cycle abnormality
Insufficient refrigerant or a closed valve
F93
Outdoor compressor abnormal revolution
Power module or compressor lock
F95
Outdoor cooling high pressure protection
Refrigeration system, outdoor airflow
F97
Compressor overheating protection
Insufficient refrigerant
F99
Outdoor DC peak detection
Power module or compressor lock

What does H11 mean on a Panasonic air conditioner?

H11 is an indoor/outdoor communication error: the two units have stopped talking. Panasonic’s service manual points to the wiring and terminals between the units and to the control boards. Switch the system off at the isolator for a few minutes; if H11 comes back, an engineer needs to test the wiring and boards before any board is replaced.

What do H19, H97 and H99 mean?

H19 is an indoor fan motor lock and H97 an outdoor fan motor lock: check that nothing blocks the fan, such as leaves or ice outside. H99 is the indoor unit’s freeze protection in cooling: Panasonic lists a dirty air filter or heat exchanger among the causes, so clean the filter first. If H99 keeps returning, the coil needs a proper clean and the refrigerant charge a check.

What do F91, F95, F97 and F99 mean?

These are outdoor and refrigerant faults. F91 is a refrigeration cycle abnormality, which Panasonic puts down to insufficient refrigerant or a closed valve; F97 compressor overheating, also linked to low refrigerant; F95 high pressure in cooling, often a blocked outdoor coil or airflow; F99 a DC peak, pointing to the power module or a locked compressor. Low refrigerant means a leak, and refrigerant work needs an F-Gas engineer.

Panasonic PACi and ECOi use different codes

Commercial PACi systems show E, F, H, L and P codes on the wired remote, and the same code can mean something different: on PACi, F04 is the discharge temperature sensor and H31 an inverter fault, while on Etherea H31 is a pool sensor fault. Give the engineer the model with the code. ECOi VRF systems need the outdoor unit’s own service manual.

When to call an engineer

Panasonic’s instruction for every code is to switch the unit off and give the code to an authorised dealer. Before you call, clean the filters, check the outdoor unit is clear and note the code and the model of both units. Anything that involves the refrigerant, such as a leak search, a pressure test or a gas top-up, is work for an F-Gas certified engineer. LE Company engineers hold F-Gas certificates. For other makes, see our guides to Daikin error codes, Mitsubishi air conditioner error codes, Fujitsu air conditioner error codes, LG air conditioner error codes, Samsung air conditioner error codes, Toshiba air conditioner error codes and Hitachi air conditioner error codes.

Book a Panasonic air conditioning repair in London

LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer reads the stored fault codes and finds the cause. The cost of the repair is agreed with you before any work starts. We fit only original parts, covered by the warranty of the company that supplies them. See our Panasonic air conditioner repair, air conditioning repair in London, commercial air conditioning repair and emergency air conditioning repair pages, read our frequently asked questions, or call +44 20 3603 7172, Monday to Saturday, 8am to 8pm.

Book an engineer

Leave your details and what is wrong. The bookings team will email you the call-out cost and the times an engineer can come. Call-out from £175 + VAT, including the first 30 minutes on site.