LG air conditioner error codes: what they mean and what to do
An LG air conditioner shows a fault as CH and a number, for example CH05 (communication between the indoor and outdoor units), CH10 (indoor fan motor lock) or CH38 (refrigerant leak), and the number itself tells you where to look: CH01 to CH12 are indoor unit faults and CH21 and above are outdoor unit faults. This guide from LE Company, air conditioning engineers in London, takes the meanings from LG’s own service manuals and help pages and explains what you can check and when to call an engineer. For repairs, see our LG air conditioner repair page.
Every repair we do starts with checking and cleaning the system. Many of the faults behind these codes, from a frozen indoor coil to an overheated outdoor unit, come from blocked filters, a dirty coil or a blocked condensate drain, and after a proper service the code often does not come back. That is why we service first and replace parts only when a test shows the part is faulty. See what an air conditioning service covers.
How LG shows an error code
Units with a display show CH followed by the number, such as CH05; on Multi V systems the code appears on the wired remote as CH 01. Wall units without a number display flash two LEDs instead: one LED counts the units digit and the other the tens digit, with a pause between them. LG’s own documents are not consistent about which LED is which, so count the flashes on each LED and check against your model’s manual. On the outdoor unit board a red LED flashes the tens and a green LED the units. Outdoor faults can take a while to reach the indoor display, because the indoor unit shows them only after they repeat.
LG air conditioner error codes (CH codes)
Meanings from LG’s wall-mounted inverter service manual and Multi F installation manual, with the Multi V meaning where LG gives a different one. Reset means LG’s standard owner step: switch off at the plug or breaker, wait about 5 minutes, switch on; if the code returns, call service.
Code | Home split / Multi F | Unit | Multi V, if different |
CH01 | Indoor room temperature sensor error | Indoor | - |
CH02 | Indoor inlet pipe sensor error | Indoor | - |
CH03 | Wired remote control error | Indoor | Remote / zone controller communication |
CH04 | Float switch / drain pump error | Indoor | Drain overflow |
CH05 | Communication error between indoor and outdoor units | Indoor | - |
CH06 | Indoor outlet pipe sensor error | Indoor | - |
CH07 | Different mode operation (multi-split units in different modes) | Indoor | - |
CH09 | Indoor EEPROM error | Indoor | - |
CH10 | Indoor BLDC fan motor lock | Indoor | Poor fan motor operation |
CH12 | Indoor middle pipe sensor error | Indoor | Hydro Kit inverter PCB error |
CH21 | DC peak (IPM fault) | Outdoor | - |
CH22 | AC input current too high (CT2) | Outdoor | - |
CH23 | DC link low voltage | Outdoor | DC link low or high voltage |
CH26 | DC compressor position error (failed to start) | Outdoor | Compressor start failure / locked |
CH27 | PSC / PFC fault (AC to DC converter over-current) | Outdoor | - |
CH29 | Compressor phase over-current | Outdoor | - |
CH32 | Inverter compressor discharge pipe overheat | Outdoor | Compressor 1 high discharge temperature |
CH34 | High pressure | Outdoor | High pressure |
CH35 | Low pressure | Outdoor | Low pressure |
CH36, CH38 | Refrigerant leakage detection | Outdoor | CH36: low compression ratio |
CH41 | Discharge pipe sensor error | Outdoor | - |
CH44 | Outdoor air sensor error | Outdoor | - |
CH45 | Condenser middle pipe sensor error | Outdoor | Heat exchanger sensor |
CH46 | Suction pipe sensor error | Outdoor | - |
CH53 | Communication error, outdoor from indoor | Outdoor | - |
CH54 | Outdoor unit not wired properly (for example reversed phase) | Outdoor | - |
CH60 | Outdoor PCB EEPROM error | Outdoor | - |
CH61 | Condenser coil temperature too high | Outdoor | - |
CH62 | Heat sink temperature high | Outdoor | - |
CH65 | Heat sink thermistor open or short | Outdoor | - |
CH67 | Outdoor BLDC fan motor lock | Outdoor | - |
CH72 | 4-way valve transfer failure | Outdoor | - |
What does CH05 mean on an LG air conditioner?
CH05 is a communication error between the indoor and outdoor units. LG’s own advice is a power reset: switch off at the breaker, wait about 5 minutes and switch on. If CH05 appears straight after an installation or building work, it is usually the wiring between the units, and the installer should check it. If it comes back on a system that has run for years, the connections, the outdoor unit’s power and the boards need testing. CH53 is the same kind of fault seen from the outdoor side.
What does CH38 mean on an LG air conditioner?
CH38, and CH36 on home splits, is refrigerant leakage detection. LG’s help pages describe it as the unit being low on refrigerant, and LG’s service manual tells the engineer to find where the leak is. Refrigerant does not get used up, so a system that is low has a leak, and topping it up without finding the leak only buys time. On Multi V systems CH36 means something else, a low compression ratio. Refrigerant work needs an F-Gas certified engineer.
What do CH10 and CH67 mean?
CH10 is an indoor fan motor lock and CH67 an outdoor fan motor lock: the fan is not turning as it should. Before calling, check the fan is not blocked by debris, leaves, ice or snow, and switch the power off and on. On indoor units a fan drum clogged with dust can also slow the motor, which is one more reason a full service comes before a new motor.
What do CH23, CH26 and CH61 mean?
CH23 is DC link low voltage on the inverter, and on Multi V low or high voltage, so a weak or unstable supply can cause it. CH26 means the compressor failed to start (a position error), which needs the compressor and inverter board tested. CH61 means the condenser coil in the outdoor unit is running too hot: LG says to clear the space around the outdoor unit, clean the indoor filter if it happens in heating, and reset the power, because CH61 does not clear by itself. A dirty outdoor coil is the usual cause, and cleaning it is part of every service we do.
When the same CH code keeps coming back
A code that returns every time the system starts is a fault, not a glitch. On one LG system in a Putney home the air conditioning stopped and showed CH every time it was switched on. Our engineers found the main control board and the temperature sensors (thermistors) at fault and replaced them; LG’s supplier sells the discharge and suction thermistors only as a set of three. The same home has a ducted LG system where one room stayed warm; see LG air conditioning not cooling one room.
When to call an engineer
LG’s instruction for most codes is a power reset and then service if the code returns. Before you call, clean the filters, check the outdoor unit is clear, note the CH code, the model of both units from the rating plates and when the fault happens. Anything that involves the refrigerant, such as a leak search, a pressure test or a gas top-up, is work for an F-Gas certified engineer. LE Company engineers hold F-Gas certificates. For other makes, see our guides to Daikin error codes, Mitsubishi air conditioner error codes and Fujitsu air conditioner error codes.
Book an LG air conditioning repair in London
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer reads the stored fault codes and finds the cause. The cost of the repair is agreed with you before any work starts. We fit only original parts, covered by the warranty of the company that supplies them. See our LG air conditioner repair, air conditioning repair in London, commercial air conditioning repair and emergency air conditioning repair pages, read our frequently asked questions, or call +44 20 3603 7172, Monday to Saturday, 8am to 8pm.