Rational oven leaking water at the back or underneath: two causes we find
When a Rational combi oven leaks water at the back or underneath, LE Company engineers almost always find one of two causes. The first is the pipes behind the oven: the hoses that connect the waste water container at the back and the overflow from the rinse tablet container are poor quality, come loose or crack, and the usual fix is to replace the whole set. The second is water escaping through the overflow because scale has formed at the inlet of the steam generator and blocks its filling, which looks as if the oven is taking in far too much water. Both are repairable, and neither should be left, because water at the back of the oven runs towards the electrics; moisture at the plug contacts is one of the causes RATIONAL lists for Rational Service 10. For our full service, see Rational oven repair in London.
Why is my Rational oven leaking water at the back?
Behind the oven there is a waste water container, and the rinse tablet container has an overflow. The pipes that join them are, in our experience, a weak point on combi ovens: they are not strong, they work loose and they split with heat and age. The water then appears at the back of the oven or as a pool underneath it, often only during cleaning, when the most water runs through.
We check these pipes first, and in most cases we replace the whole set rather than one piece, because the others are the same age and will be next. Almost all of the work is done from the front of the oven. The one exception is the pipe behind the rinse pump: to reach it, we open the back of the oven and remove the rear plate of the rinse pump, so that the pipe can be fixed back securely.

Water coming out of the overflow: scale at the steam generator inlet
The second leak comes out through the overflow. It looks as if the water pressure filling the steam generator is much higher than it should be, and owners often suspect the water supply or a valve. In fact it usually means scale has built up at the steam generator inlet. The scale blocks the filling, the water cannot get into the steam generator where it should, and it goes out through the overflow instead. Turning the water pressure down does not fix it; the inlet has to be opened and cleared of scale, and the steam generator descaled.

Before opening the steam generator: have a spare pump housing
This is the lesson that saves an oven. Before anyone starts opening the steam generator, there must be a spare plastic housing for the drain pump on hand. If scale has got into the existing housing, it will not come apart: it breaks when you try to open it, and then the oven does not work at all until a new one arrives. The same scale is what blocks the pump and causes Rational Service 110 after descaling.
Leaking at the front instead?
Water at the front, under the door, has different causes: a worn or misplaced door seal, or jet connections that leak under the door during cleaning. A leaking door seal also stops the cleaning with Rational Service 25; see Rational cleaning aborted or not cleaning properly. A leak inside, from a steam generator tube or seal, can leave the oven without steam: see Rational oven not steaming. For any code on the display, see our Rational error codes guide.
What you can do while you wait for an engineer
- Note where the water appears: at the back, underneath, at the front under the door, and whether it happens during cooking, cleaning or all the time.
- If water is pooling, switch the oven off, close the water tap to the oven and keep the floor dry.
- Do not start more cleaning cycles: cleaning pushes the most water through the pipes and the overflow.
- Do not try to open the steam generator or the pump housing yourself: without a spare housing a scaled one breaks.
Service first
Every repair we do starts with checking and cleaning the oven. Both leaks start with things a service looks at: ageing pipes at the back and scale building up at the steam generator inlet. A regular Rational oven service checks the pipes, descales the steam generator and its inlet and looks at the water treatment before water reaches the floor. For how far scale can go, see the Rational steam generator full of scale.
Book a Rational repair in London
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause of the fault. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. We repair Rational iCombi Pro, iCombi Classic, SelfCookingCenter and CombiMaster Plus in restaurants, hotels and pubs; see commercial oven repair and catering equipment repair, or call +44 203 603 7172, Monday to Saturday, 8am to 8pm.