Rational Service 10 error: SC pump fault, causes and reset


On a Rational iCombi Pro (S_10), iCombi Classic (10) or an older SelfCookingCenter and CombiMaster Plus (E10), Service 10 means a malfunction in SC-Automatic: after the SC pump should have pumped the steam generator empty, the level electrode still signals a “full” water level. It is the same fault as Rational Service 110, with one difference given in RATIONAL’s iCombi troubleshooting guide: when cleaning chemicals are still in the steam generator the oven reports 110, and when they are not it reports 10. In practice, 110 is what you find when the oven was left on a cleaning cycle, and 10 is the same fault during normal cooking. The parts to check are the same: the SC pump, the drain line and pump housing, the level electrode, the combi water box, the plug connections and the steam generator reference volume. For our full service, see Rational oven repair in London.
Pump impeller from a Rational SelfCookingCenter blocked with food debris and grease, a cause of the Service 10 SC pump fault

What does Service 10 mean on a Rational oven?

The SC pump pumps water out of the steam generator, and after pumping, the level electrode should detect an “empty” level. Service 10 is shown when the pumping has run but the electrode and the electronics still report “full”. Either the water really is still there, because the pump or its drain is blocked, or the water has gone and the electrode or its connection is giving a false reading. Unlike Service 110, which stops the oven in an interrupted cleaning cycle, RATIONAL’s operating instructions say that with Service 10 you can still cook; the fault should be reported to a service engineer. For the other codes, see our Rational error codes guide.

Service 10 or Service 110: what is the difference?

  • Service 10: the fault happens during normal cooking, with no cleaning chemicals in the steam generator: after pumping out it still reads full. Cooking can continue.
  • Service 110: the same fault while the oven has been left on a cleaning cycle and cleaning chemicals are in the steam generator, so it appears during cleaning and the oven is out of operation until it is repaired.
  • The causes and the checks are the same in RATIONAL’s guide, apart from one: for Service 10 it also lists moisture at the plug contacts.
So if Service 10 keeps coming back, it is worth fixing before the next cleaning: the same blocked pump is what turns into Service 110 halfway through a cleaning cycle.

What causes Service 10?

Because it is the same pump and the same electrode as Service 110, what we find on 110 calls applies here. The most common cause in our experience is limescale: after descaling, small flakes break loose and get into the SC pump, usually within two or three days. On older SelfCookingCenter ovens we also find the pump impeller blocked with food debris and grease. RATIONAL’s guide lists these causes:
  • SC pump clogged or blocked: the pump is cleaned and checked for correct operation, and replaced if it is defective. A failure of the pump itself is possible, but in our experience very unlikely.
  • A blocked steam generator drain line, or a clogged SC pump housing between the steam generator and the impeller.
  • A soiled level electrode, or one that misreads the level: cleaned, or replaced.
  • A blocked combi water box, cleaned by hand or replaced.
  • Moisture at the plug contacts of the level electrode or the pump. The guide says to find the water leak and fix it: see Rational oven leaking water at the back or underneath.
  • A poor plug connection at the level electrode, or between the pump and the control board.
  • A wrong steam generator reference volume: the current filling volume must not be more than 20% below the reference, and a new reference can only be measured on a descaled steam generator.
Rational oven drain hose packed with limescale, which stops the SC pump emptying the steam generator and causes Service 10

How we fix Service 10 on a Rational

On an iCombi Pro we first run the “iCareSystem” module test and export all data to a USB stick, as RATIONAL asks before any part is disconnected; on an iCombi Classic the data is downloaded and the time of the error noted. Then:
  • Isolate the oven at the wall, not at its own switch. On a Rational oven one phase stays live when the oven is switched off. Anyone touching the back plate inside with the supply still connected can get an electric shock.
  • Remove the SC pump and clear the pump and its housing of scale or debris, and check that the impeller turns freely.
  • Check inside the steam generator for loose pieces of scale that would block the pump again, and check the quenching behind the pump.
  • Check the level electrode and the plugs for dirt, damaged contacts and moisture, and find where any water is coming from.
  • Seals: the rubber seals that are disturbed are lubricated with silicone, or better, replaced.
  • Reference volume: if it is wrong, the steam generator is descaled and a new reference volume measured in the service menu.
Rational service level water menu showing the steam generator volume after descaling, checked when fixing Service 10

How to reset Service 10 on a Rational

As with Service 110, there is no separate reset: once the cause is cleared and the oven is restarted, the message does not come back. If it returns, the cause is still there. If a Service 42 error appeared at the same time, the “iCareSystem” module test is used to check the function and reset it. Our step-by-step for scale in the pump, with photos, is in Rational Service 110.

Service first

Every repair we do starts with checking and cleaning the oven. Scale after descaling, a drain nobody has looked at and seals that have dried out cause most pump faults. A regular Rational oven service descales the steam generator, rinses it properly, and checks the pump, the drain and the plugs before they show a code. See also Rational cleaning aborted or not cleaning properly, Rational Service 25 and Rational steam generator full of scale.

Book a Rational repair in London

LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause of the fault. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. We repair Rational iCombi Pro, iCombi Classic, SelfCookingCenter and CombiMaster Plus in restaurants, hotels and pubs; see commercial oven repair and catering equipment repair, or call +44 203 603 7172, Monday to Saturday, 8am to 8pm.