Rational oven not steaming: causes and fixes from our repairs
When a RATIONAL combi oven stops steaming, the fault is almost always in the steam generator and the parts around it, and most often it is scale. LE Company has handled more than 340 RATIONAL requests in London since 2022, and on ovens that would not steam our engineers most often found a water level sensor coated in scale, a steam generator that needed descaling, or a failed part that heats the steam generator: a contactor, a solid-state relay, a high-limit safety thermostat or, on gas models, the steam generator igniter. Many of these ovens keep cooking with dry heat and show a Service code, so the kitchen can keep working while the steam is out.

Why is my Rational oven not steaming?
Here is what our engineers have found on RATIONAL ovens that would not steam, in the order we check them:
1. Scale on the water level sensor or in the steam generator
The steam generator fills with water up to a level that a sensor measures. When scale builds up on the sensor, the oven cannot read the level, and when scale fills the generator, it cannot make steam. The most common repair on these ovens is cleaning the water level sensor and descaling the steam generator, sometimes followed by a steam generator reset. On one oven we removed a piece of scale from the water meter.
2. A failed contactor, relay or high-limit thermostat
The steam generator heating is switched by a contactor or a solid-state relay and protected by a high-limit safety thermostat. We have replaced a faulty heating contactor for the steam generator, found a failed high-limit thermostat on a steam generator, and replaced a burnt solid-state relay on an iCombi Pro showing Service 44, a malfunction in the steam heating system: read Rational iCombi Pro Service 44: a burnt relay and scale.

3. On gas ovens: the steam generator igniter
A gas RATIONAL heats its steam generator with its own burner. We have found a broken igniter lock on a steam generator and replaced the igniter, and repaired a spark igniter.
4. Leaks: a broken tube, a cracked seal or loose clamps
Steam that escapes never reaches the cabinet. We have found a broken high-temperature steam generator tube, replaced clamps, and found a crack in a steam generator seal, which we advised replacing before using steam or the washing cycle again.
5. Water supply and the control
If the water pressure is too low, the steam generator does not fill; on one oven the water supply line had to be investigated because the oven failed its test on pressure. And a Service code can be the control rather than the steam generator: on a SelfCookingCenter showing Service 13, the code cleared after we reprogrammed the control unit, as described in our job on a Rational cooking unevenly.
Rational cooking with dry heat only: is it safe to keep using it?
When the display says "Maintenance required, cooking with dry heat", the oven has switched off steam to protect itself and you can usually keep cooking with dry heat until the engineer comes. Do not keep resetting the error; book a repair, because scale left in the generator keeps growing. Our article on a Rational steam generator full of scale shows what it looks like inside, and RATIONAL error codes explained lists the Service codes for the steam generator, including Service 12, 13 and 14.
How to stop scale building up
- Fit and change the water filter on time; on one hotel oven we exchanged a Brita Purity C Steam 1200 cartridge and descaled the whole water system.
- Run the descaling programme when the oven asks for it.
- Have the steam generator and water level sensor serviced once a year in hard-water London.
See our RATIONAL oven repair in London page, commercial oven repair and planned preventative maintenance for kitchens that cannot afford a breakdown.
Questions
Why is my Rational oven not steaming?
Most often scale on the water level sensor or in the steam generator. Other causes LE Company engineers find are a failed steam generator contactor, solid-state relay or high-limit thermostat, a faulty igniter on gas models, a leaking tube or seal, and low water pressure.
What does cooking with dry heat mean on a Rational?
The oven has detected a steam generator fault, switched off steam and kept the dry-heat function working. You can usually keep cooking until the engineer comes, but book a repair rather than resetting the error.
How do you fix a Rational steam generator?
Clean the water level sensor, descale the steam generator, check its heating contactor or relay and its safety thermostat, check tubes, seals and clamps for leaks, and test the water supply. Then run a steam test.
How often should a Rational steam generator be descaled?
Run the descaling programme whenever the oven asks for it, change the water filter on time, and have the steam generator serviced at least once a year in hard-water areas such as London.
Book a RATIONAL engineer in London
LE Company’s engineers are RATIONAL certified and Gas Safe registered. The call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause; the cost of any repair is agreed with you before work starts, and we fit only genuine RATIONAL parts. For an emergency we dispatch an engineer within an hour and aim to be with you within 4 hours, traffic permitting. Call +44 203 603 7172.