Viking fridge and freezer not cooling: the compressor is not starting
When both the fridge and the freezer of a Viking are warm, the most likely cause is the one part they share: the compressor is not starting. Either the compressor itself has failed, or the electronics that start it (the inverter, also called the compressor control unit, or a relay on the main board) are not giving it power. LE Company engineers repair Viking refrigerators in London, and on a Viking built-in side-by-side in Belgravia in November 2026 we proved the compressor had failed: it would not start with a test inverter or with a direct start. If only the fridge is warm and the freezer is cold, the cause is different, usually ice on the evaporator or a failed defrost system (see below).

Why are my Viking fridge and freezer both not cooling?
On a Viking side-by-side like the one below, one compressor cools both sections, so when it stops, both warm up together. On many of these units it is a variable-speed compressor driven by its own electronic control unit, the inverter. When the compressor does not run, the fault is in one of four places:
- The condenser is blocked with dust. The compressor overheats and its protection stops it. This is why every repair starts with checking and cleaning, and sometimes a clean is the whole repair.
- The inverter (compressor control unit) has failed. On a Viking side-by-side whose freezer and then fridge kept warming up and recovering a day or two later, our engineers replaced the inverter.
- The main board is not sending power. On a Viking freezer that was not freezing well, we found unstable power to the compressor: no neutral from the board, caused by a bad connection on one relay, which we fixed.
- The compressor itself has failed. That is what we found in Belgravia, and it means a compressor replacement.
Recent job: Viking compressor not running
In November 2026 we were called to a home in Belgravia: a Viking built-in side-by-side fridge freezer (model EVCSB483SS) was not cooling at all. On arrival the compressor did not respond. Our engineer went step by step:
- Deep cleaning of the unit, so that dust and heat could be ruled out.
- The compressor was checked: no response.
- The unit’s inverter was swapped for a test inverter, to rule out the electronics: the compressor still did not start.
- A direct start was tried with a compressor starter: no response.
- The resistance of the compressor windings was measured: within range.
A compressor that will not start with a known good inverter or with a direct start has failed, even when its windings measure correctly. The recommendation was a compressor replacement.

Why a Viking compressor needs the right test
The compressor in this Viking is an Embraco VEGY 6H, and its label says it must be used only with an Embraco control unit: it runs on three-phase power at 53 to 150 Hz made by the inverter, and the label warns that connecting it directly to the mains will damage it permanently. So a dead inverter and a dead compressor look the same from the outside, and the only way to tell them apart is to test each one with known good equipment, as above. Replacing the compressor when the inverter is at fault, or the other way round, wastes the customer’s money.
Viking refrigerator not cooling but freezer works
If the freezer is cold and only the fridge is warm, the compressor is running, and the cold is not reaching the fridge. On one Viking fridge freezer our engineers found the evaporator and the air flow to the fridge iced up, because the defrost element and the defrost terminator had failed. Ice on the evaporator, a failed defrost system and a failed fan are the usual causes. See fridge freezer not cooling: causes and fixes and, for a similar fault on another American brand, Sub-Zero fridge not cooling.
What you can check yourself
- Is the display on and the light working? If not, check the fuse or breaker first.
- Listen at the grille: if the fans run but the compressor never starts, it is the compressor or what starts it.
- Keep the grille and the condenser clear of dust.
- Do not keep switching the unit off and on: move the food to another freezer and call an engineer.
Do Sub-Zero parts fit a Viking fridge?
On older units, yes. LE Company engineers repair both brands, and an older Viking built-in and an older Sub-Zero are practically identical inside, with the same parts fitted; it looks as if the two brands took their parts, and perhaps their designs, from the same place. Both are built around Embraco compressors running on R134a (Sub-Zero’s own technical data for the 600-3 series lists Embraco compressors), and the inverter models of both use Embraco variable-speed compressors driven by an Embraco control unit, like the VEGY 6H and its control unit in the Viking above. So a compressor or an inverter does not have to come through Viking, which can be slow. What matters is matching the exact compressor and control unit codes on the labels, and we carry test inverters for both brands.
One difference matters when you diagnose: many Sub-Zero built-ins have two compressors, one for the fridge and one for the freezer, so on a Sub-Zero one warm section points to that section’s compressor or inverter. On a Viking side-by-side with one compressor, both sections warm up together.
Viking compressor replacement
A compressor replacement is work on the sealed refrigeration system: the refrigerant (R134a on this model) is recovered, the old compressor is cut out and the new one brazed in, the system is evacuated and recharged. It is done by an F-Gas registered engineer. The cost of the repair is agreed with you before any work starts. LE Company has handled about 80 Viking fridge and freezer jobs in London since 2022; see our Viking fridge repair page, Viking repair in London and fridge freezer repairs.
Book a Viking fridge repair
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause. 12-month guarantee on parts — we fit only original manufacturer parts. Our engineers are F-Gas registered. Call +44 203 603 7172, Monday to Saturday, 8am to 8pm.