Polar ice machine fault lights: why it is not making ice
A Polar ice machine that stops making ice usually tells you why with its five lights: RUN, CLEAN, FAULT, ICE FULL and WATER LOW. According to Polar’s instruction manual for the T316 and GL192, WATER LOW means no water is reaching the machine (supply off, blocked filter or pressure below 100 kPa), ICE FULL means the bin is full or the room is too cold, and a FAULT light that flashes once, twice or three times every six seconds points to a failed ice, ambient or water temperature sensor. LE Company services and repairs Polar, Scotsman and other ice machines in London pubs, bars and restaurants. For our full service, see ice maker repair in London.

What do the lights on a Polar ice machine mean?
This table is taken from the troubleshooting section of Polar’s instruction manual for the T316 and GL192. Other Polar models may differ, so check the manual for yours.
Light | What Polar says it means | What to do |
WATER LOW on | Water not connected, water filter blocked, or water pressure too low | Check the supply is on, clean the filter; pressure should be 100–400 kPa (14.5–58 psi) |
ICE FULL on | Ice bin full, or room temperature too low | Empty the bin; move the machine somewhere warmer |
FAULT on, or WATER LOW, ICE FULL and FAULT flashing together | Water box blocked and cannot tilt, or a motor system fault | Switch off, remove some ice, gently tilt the water box, restart after 3 minutes; if it persists, call an engineer |
FAULT flashes once every 6 s (or FAULT on, RUN off) | Ice sensor fault: the machine cannot make ice | Engineer visit |
FAULT flashes twice every 6 s (or ICE FULL on, RUN off) | Ambient temperature sensor fault | Engineer visit |
FAULT flashes three times every 6 s (or WATER LOW on, RUN off) | Water temperature sensor fault | Engineer visit |
CLEAN flashing with an alarm | About 1,500 ice cycles (roughly three months) since the last clean | Run the automatic cleaning cycle |
Why is my ice machine not making ice?
Start with what the lights say. If the compressor runs but no ice is made, Polar’s manual lists a refrigerant leak or a blockage in the refrigerant system: that needs an F-Gas registered engineer, not a reset. The manual also says the machine should not be used below 10°C ambient. In our engineers’ experience on commercial ice machines, the most common reasons are simpler: a blocked water filter, scale on the water system and a condenser clogged with dust, which makes the machine overheat and slow down. That is why every repair we do starts with checking and cleaning the machine.
How often should a Polar ice machine be cleaned and descaled?
Polar recommends descaling every three months, or more often in hard water areas, and suggests a water softener on the supply. London water is hard. The automatic cleaning cycle takes about 30 minutes; the GL192 needs 3 litres of ice-machine cleaner in the reservoir. After cleaning, Polar says to discard the ice from the first three cycles. If WATER LOW lights during cleaning, the clean has failed: switch off, wait for the light to go out and repeat.
Scotsman and other ice machines
Scotsman self-contained machines such as the AC 107 work on the same principle: water, a refrigeration circuit and a condenser that needs air. The meaning of their alarm lights differs by model, so read the code from the machine’s own manual before acting on it. The same rules apply: keep the condenser clean, keep the water filter in date and descale on schedule.

Ice machine service in London
A regular service keeps ice clean and the machine running through busy evenings. See pub equipment maintenance, restaurant equipment maintenance and catering equipment maintenance. For other cold equipment, see commercial refrigeration repair and ice cream machine repair (Carpigiani 191 error codes); for a domestic fridge, fridge freezer not cooling.
Book an ice machine repair in London
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause of the fault. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. Our engineers are F-Gas registered. Call +44 203 603 7172, Monday to Saturday, 8am to 8pm.