Carpigiani 191 error codes and display messages
On a Carpigiani 191 or 193 soft serve machine, WAS on the display means a wash is due within the next few days, and W followed by a number counts the days until the next wash. Alarms start with A: A01 to A05 stop the machine (thermal protections, safety thermostats, tank sensor), A09 means the front lid is open, and A11 means the high pressure switch has tripped. LE Company repairs Carpigiani and other soft serve and gelato machines in London; since 2022 we have handled about 200 ice cream machine requests. For our full service, see ice cream machine repair in London.

What does WAS mean on a Carpigiani?
WAS is a reminder, not a fault: the machine is telling you the wash cycle is due in the last few days before cleaning. Because the display has only three seven-segment digits, WAS reads like “uA5”, and the countdown W with a number reads like “u” followed by digits. Clean the machine as the manual describes and the countdown starts again.

Carpigiani 191 alarm codes
The meanings below are from the published troubleshooting guide for the Carpigiani 191 and 193. Check your own model’s manual: other Carpigiani machines use different codes.
Code | Meaning | What happens |
A01 | Thermal protection tripped | Machine stops |
A02 | Compressor thermal relay or protection tripped | Machine stops |
A03 / A04 | Tank / cylinder safety thermostat tripped | Machine stops |
A05 | Tank sensor faulty | Machine stops |
A06 | Cylinder sensor faulty | Stops during pasteurisation or storage |
A07 / A12 | Tank / cylinder evaporator sensor faulty | LED blinks, machine keeps running |
A09 | Safety magnet switch: front lid open | Close the lid |
A11 | High pressure switch tripped | Stops after repeated trips |
A22 | Production ran over 15 minutes without reaching HOT | Alarm shown |
A24 | Portion count reached the “last cones” setting | Machine goes to storage |
A30 | Tank above 15°C while stopped | Forces a pasteurisation cycle |
LOW | Mix running out | Add mix |
Stb | Standby, or product not ready to serve | Wait |
PHS | Stopped by the phase controller | Check the supply |
Why is my ice cream machine not freezing?
These are the causes in our job records on soft serve and gelato machines, roughly in order:
- A blocked condenser. Dust on the condenser makes the refrigeration overheat; the compressor trips and the product stays soft. The Carpigiani guide also says that a compressor that starts and stops within seconds points to poor air circulation (or no water on water-cooled machines).
- Low refrigerant. On one Carpigiani whose ice cream came out milky after the first portion, the refrigeration circuit needed regassing with R404A by our F-Gas engineer.
- Drive faults. A failed gearbox (reductor) on the main cylinder, a burnt beater motor, a worn belt or a seized bearing. On one 191 SP the reductor had failed and the machine would not produce ice cream at all.
- Electrical faults. Blown transformer fuses or thermofuses, failed relays, and control boards reporting a voltage error.
What you can check yourself
- Keep the vents clear and clean dust from the condenser grille.
- Close the front lid properly (A09) and tighten its knobs evenly.
- Keep the mix topped up (LOW) and do not ignore the WAS reminder.
- If the machine stops on an A01 to A05 alarm, or keeps tripping the pressure switch, call an engineer rather than resetting it again and again.
Ice cream machine service in London
Every repair starts with checking and cleaning, including the condenser. See also ice machine fault lights, commercial refrigeration repair and restaurant equipment maintenance.
Book an ice cream machine repair in London
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. Our engineers are F-Gas registered. Call +44 203 603 7172, Monday to Saturday, 8am to 8pm.