Rational oven cooking unevenly: the lower fan motor was failing and the oven could not tell


When a RATIONAL combi oven cooks the top shelves faster than the bottom ones, look at the circulation fans first. LE Company engineers found exactly this on a RATIONAL SelfCookingCenter SCC 201 E in a commercial kitchen in Croydon, South London, in November 2026: the lower fan motor was no longer reaching its rated output. The oven passed its self-test and showed no fan error at all, because its control unit did not detect that the motor was under-performing.

We went: food cooking faster at the top than at the bottom

The chef told us the oven was not cooking as it normally does: food at the top was done before food at the bottom, and he suspected the top fan was working better than the bottom one. A service of the oven was also booked.

We found: a lower fan motor that kept slowing down

  • On 4 November 2026 we ran the self-test three times. It passed every time, with no error.
  • We switched the oven to heating mode and watched the fans. The lower fan motor periodically slowed down for no visible reason, and the oven showed no error for it.
  • The display also showed Service 13 (steam generator water level), so the oven was cooking with dry heat only. The level electrode was clean.
  • We deliberately did no cleaning that day: first the cause of the slowdown had to be found.
RATIONAL SelfCookingCenter display showing Service 13, maintenance required, cooking with dry heat
The question was whether the control unit was slowing the motor down, or the motor was failing by itself. On the next visit, on 5 November, we reprogrammed the oven's control unit; it took two attempts. Then we ran the control unit's own motor test: the lower fan motor did not reach its rated output. The motor was at fault. It sends no error back to the system, which is why the oven had never shown one. After the reprogramming, Service 13 cleared and did not come back.

We did: proved the motor, then ordered the part

  • Reprogrammed the control unit and ran the motor test, which proved the lower fan motor faulty.
  • Recommended replacing the lower fan motor with a genuine RATIONAL part, then re-testing the fans and the cooking from top to bottom.
  • Advised the customer not to rely on the oven until the motor is replaced: the control unit does not see the fault, and a fan that does not move enough air can lead to burnt-out heating elements.
  • Left the service and cleaning for the return visit, once the new motor is in.

Why is my Rational oven cooking unevenly?

In a combi oven the fans spread the heat. If one fan slows down or stops, that part of the cabinet cooks more slowly, and food cooks unevenly from top to bottom or side to side. Check that nothing blocks the fan guard and the air inlet filter is clean; if it still cooks unevenly, a fan motor or its control needs testing, and a self-test that passes does not rule the motor out. See our RATIONAL oven repair in London page, RATIONAL error codes explained for Service 13 and other codes, and other RATIONAL jobs: a fan impeller out of balance that damaged a heating element, Service 44 on an iCombi Pro and a steam generator full of scale. For the rest of the kitchen, see commercial oven repair and commercial kitchen equipment repair.

Questions

Why is my Rational oven cooking unevenly?

Most often a circulation fan that has slowed down or stopped, or a blocked air inlet filter. On a RATIONAL SelfCookingCenter SCC 201 E in Croydon, LE Company found the lower fan motor not reaching its rated output, so food at the top cooked faster than at the bottom.

Will a Rational oven show an error if a fan motor is failing?

Not always. On this job the oven passed its self-test three times and showed no fan error, because the motor sent no error and the control unit did not detect that it was under-performing. The control unit's motor test proved the fault.

What does Service 13 mean on a Rational SelfCookingCenter?

Service 13 relates to the steam generator water level and top-up; the oven keeps cooking with dry heat only. On this oven Service 13 cleared after the control unit was reprogrammed and did not return.

Can I keep using a Rational oven with a failing fan motor?

It is not recommended. If the fan does not move enough air, the heating elements can burn out, and the oven may not warn you. Have the motor tested and replaced.

Book a RATIONAL oven repair

LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause. The cost of any repair is agreed with you before work starts, and we fit only genuine RATIONAL parts. For an emergency we dispatch an engineer within an hour and aim to be with you within 4 hours, traffic permitting. Call +44 203 603 7172.

Book an engineer

Leave your details and what is wrong. The bookings team will email you the call-out cost and the times an engineer can come. Call-out from £175 + VAT, including the first 30 minutes on site.