Sub-Zero repair: what our engineers find on visits in London
On the Sub-Zero fridges LE Company repaired in London in October and November 2026, the faults were heaters, compressor drives and neglect. Where we tested the main control board, it was fine. Every repair we do starts with checking and cleaning the appliance, because a Sub-Zero that has not been serviced fails in ways that look like electronics but are not. For repairs, see our Sub-Zero repair page, and for codes, Sub-Zero error codes.

Sub-Zero drawer fridge trips the electrics
A new Sub-Zero two-drawer fridge-freezer with ice maker kept tripping the RCD. We ran the defrost test: the breaker tripped as soon as the defrost heaters were switched on. The main control board was intact. All three heating elements of the defrost circuit were replaced, and the unit passed its test. If your Sub-Zero trips the electrics, switch it off and leave it off until it has been checked. Read the full case: Sub-Zero drawer fridge tripping the breaker.
Sub-Zero ice maker not working
On an integrated Sub-Zero fridge-freezer the ice maker had stopped: its heating elements had failed and the water inside had frozen solid. Until the elements are replaced, the ice maker cannot work.
Sub-Zero freezer not working, error 40
On a Sub-Zero PRO 48 the freezer had stopped. The service display showed error 40, a long compressor run, and an error in the lighting system. The freezer compressor would not start on its own drive; with a kick start it started and passed the test on a speed controller, which points to the compressor inverter rather than the compressor. We also found a water leak next to the compressor.
A Sub-Zero switched off for two years
A built-in Sub-Zero had been switched off for about two years. The control board passed its test, but the ice maker had jammed, there was black mould on the door liner, shelves and seals, and the condenser and drain needed cleaning. The door seals on both doors had to be replaced. A fridge that will stand unused should be cleaned, dried and left with the doors open.
Sub-Zero wine fridge compressor
On a Sub-Zero wine storage unit we replaced the compressor and cleaned the sealed system, opening it where needed. A compressor replacement is only worth doing with the sealed system cleaned at the same time.
How quickly can a Sub-Zero be repaired?
The first visit finds the cause. Simple faults are fixed there and then. Heating elements, inverters and seals are Sub-Zero parts that have to be ordered, so most of the repairs above took a return visit. Whether a repair is worth it is explained in Sub-Zero repair cost; regular service is on our Sub-Zero maintenance page.
Book a Sub-Zero repair in London
LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause of the fault. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. Call +44 203 603 7172.