La Cornue burner not lighting: causes and fixes


When a La Cornue burner will not light, or lights and goes out when you let go of the knob, the cause is usually one of four things: scale or food in the burner, a worn igniter or ignition module, a thermocouple and magnetic (flame failure) valve that no longer hold the flame, or a gas valve that is worn or leaking. That is what LE Company engineers find on La Cornue range cookers in London: since 2022 we have handled about 180 La Cornue requests, and more than 40 of them were about the hob, the burners or the ignition. For our full service, see La Cornue repair in London.
La Cornue hob with the brass burners and the simmer plate lifted for a service

Why is my La Cornue burner not lighting?

These are the causes in our job records, roughly in the order we meet them:
  • Scale and food in the burner. The brass burner heads collect scale, grease and spills; the gas ports block and the flame lights unevenly or not at all. On many services the first job is simply cleaning the scale out of every burner.
  • The flame goes out when you let go of the knob. Each burner has a thermocouple and a magnetic (flame failure) valve that keep the gas on only while there is a flame. When one wears, the burner lights while you hold the knob and dies when you release it, or the flame is unstable. Thermocouples and magnetic valves are the parts we replace most on La Cornue hobs.
  • Igniters and the ignition module. A burner that clicks for a long time before lighting, or does not spark at all, usually has a worn ceramic igniter or a failing ignition module (reignitor). On one cooker the hob had no sparks at all because the power supply to the ignition had been disconnected behind the oven cover.
  • Worn or leaking gas valves. On some models the heavy knobs wear the springs inside the valves, so the knobs drop during cooking. We have also found gas leaks at valves on leak and tightness tests. A valve with a leak is replaced, not repaired (see a La Cornue service that found a gas valve leak).
  • Cracked or burnt-out parts. We have repaired a burner with a cracked metal body, and on another cooker the simmer plate above the main burner had cracked with age and heat.
La Cornue range cooker control knobs below the hob, with the burners lifted
Cracked and broken brass burner crown on a La Cornue hob

What you can check before calling an engineer

  • Make sure the burner cap and crown are seated correctly and dry; a cap that sits crooked after cleaning is a common reason a burner will not light.
  • Clean food and grease from the burner ports with a soft brush, and let the parts dry fully.
  • When lighting, hold the knob pressed in for a few seconds after the flame appears, so the thermocouple can warm up. If the flame goes out every time you let go, that points to the thermocouple or magnetic valve.
  • If there is no spark on any burner, check that the cooker has power at its switch.
Do not take the valves or the gas pipework apart yourself. If you smell gas, turn the cooker off, open the windows and call the National Gas Emergency Service on 0800 111 999.

How we repair La Cornue burners

Every repair starts with checking and cleaning: burners descaled, safety devices tested, then leak, tightness and CO tests. Only then do we replace what has failed, usually thermocouples, magnetic valves, igniters or a gas valve. Gas work is done only by our Gas Safe registered engineers, and we fit original La Cornue parts. A burner service once a year prevents most of these faults; see how to look after your La Cornue and our La Cornue cleaning and descaling job.
La Cornue Château range with the hob top removed, showing the burners, gas pipes and valves

La Cornue oven not lighting

The oven burners work in a similar way. On one La Cornue gas oven the igniter heated but no longer reached the temperature needed to light the burner, and its wiring and fixings had rusted. See my La Cornue oven won’t work, oven not heating up, and if you are choosing a range, Lacanche vs La Cornue.

Book a La Cornue repair in London

LE Company’s call-out is from £175 + VAT and includes the first 30 minutes on site, when the engineer finds the cause of the fault. The cost of the repair is agreed with you before any work starts. 12-month guarantee on parts — we fit only original manufacturer parts. We also repair Lacanche and AGA range cookers. Call +44 203 603 7172, Monday to Saturday, 8am to 8pm.

Book an engineer

Leave your details and what is wrong. The bookings team will email you the call-out cost and the times an engineer can come. Call-out from £175 + VAT, including the first 30 minutes on site.